Determining the Risk Level
Examining the facility and determining the risk level, which dictates the type of backflow preventer required under the Israeli standard.
Proper backflow preventer installation starts with choosing the right type for the facility's risk level and the right position in the water line. Kesar Digum selects the appropriate approved device, installs it professionally, performs a commissioning test and coordinates with the water utility - nationwide.
Not every backflow preventer suits every facility. The required type - from RP through DC to simpler devices - is determined by the facility's risk level: what flows through it, whether there is a connection to chemicals, a fire-suppression system, irrigation or cooling. Installing an unsuitable device, or placing it in the wrong spot in the line, can fail inspection and require reinstallation. Kesar Digum examines the facility, determines the risk level and selects the appropriate approved device, installs it in the required position and configuration, performs a commissioning test and coordinates the registration with the water utility.
From determining the risk level and selecting the device to a commissioning test and coordination with the utility.
Examining the facility and determining the risk level, which dictates the type of backflow preventer required under the Israeli standard.
Matching an approved device of the correct diameter and grade to the facility's requirement - from among the devices that meet the standard.
Installing the backflow preventer in the required position and configuration in the water line, with full access for future inspection and maintenance.
A compliance test upon installation and coordination of the registration with the water utility, so the device enters the annual inspection cycle.
Full DetailsThe law requires a backflow preventer at any facility where there is a risk of backflow into the network. These are the common cases:
A building under construction or a facility undergoing renovation must have a suitable backflow preventer installed as part of the water connection, from day one.
Plants and businesses that use chemicals, garages and fuel stations are required to have a high-protection device.
Sprinkler and fire-suppression systems require a backflow preventer that stops standing water from the system flowing back into the network.
Irrigation systems, cooling towers and technical water systems require protection against the backflow of non-potable water.
An unsuitable device, or a faulty installation, defeats the entire purpose of the protection:
A device with a lower grade than required looks fine but does not provide protection for the actual risk level - a gap that surfaces only during an incident.
Installation in the wrong position or an unapproved device fails inspection and requires removal and reinstallation - a waste of time and money.
A facility without a suitable, registered backflow preventer does not meet the water utility's requirements, and is exposed to notices and delays in the connection.
We will examine the facility, determine the risk level and install the appropriate approved backflow preventer, including a commissioning test and coordination with the utility, nationwide.